Characteristics of color ultrasonic diagnostic instrument
1. Color Doppler ultrasound generally uses autocorrelation technology for Doppler signal processing. The blood flow signals obtained by autocorrelation technology are color-coded and then superimposed on two-dimensional images in real time to form color Doppler ultrasound blood flow images. It can be seen that color Doppler ultrasound (color ultrasound) not only has the advantages of two-dimensional ultrasonic structure image, but also provides rich information of hemodynamics. Practical application has been widely valued and welcomed, and is known as "non-traumatic angiography" in clinical practice. Its main advantages are:
① It can quickly and intuitively display the two-dimensional planar distribution of blood flow.
② It can show the direction of blood flow.
③ Helps to distinguish arteries and veins.
④ It is helpful to identify vascular and non-vascular lesions.
⑤ It is helpful to understand the nature of blood flow.
⑥ can easily understand the blood flow phase and speed.
⑦ can reliably detect shunt and backflow.
The origin, width, length and area of the blood stream can be quantitatively analyzed.
Second, the relevant technology used by color ultrasound is pulse wave. When the speed of the detected object is too high, the color flow color will make errors, which is obviously inferior to the spectrum Doppler in quantitative analysis. Today, color Doppler ultrasound instruments all have the function of spectrum Doppler, that is, color ─ dual function ultrasound.
3. Color Doppler ultrasonic flow diagram (CDF), also known as color Doppler ultrasonic imaging (CDI), the source of echo information obtained by it is consistent with that of spectral Doppler, and the distribution and direction of blood flow are displayed in two dimensions. Different velocities are distinguished by different colors. Dual power Doppler ultrasound system, which is a B-type ultrasound image shows the location of blood vessels. Doppler measures blood flow, and this combination of type B and Doppler systems allows for more precise localization of any given vessel.
1. Blood flow direction In spectral Doppler display, blood flow direction is distinguished by zero base line. Above the zero base line shows the blood flow probe, below the zero base line shows the blood flow away from the probe. In CDI, color coding indicates the direction of blood flow, and red or yellow chromatography indicates the flow to the probe (thermal color); The flow displacement probe is indicated in blue or blue-green color (cool color).
2. Vascular distribution CDI shows the blood flow in the lumen of the vessel, so it belongs to the flow channel type display. It cannot show the wall of the vessel and the outer membrane.
3. The blood vessels of liver cancer nodules can be classified by CDI. They can be distinguished as circumferential vessels around nodules and curved vessels at the inner edge of nodes. The flow vessels of nodules, the internal vessels of nodules and the outflow vessels of nodules, etc.
Next Article
Next Article
RELATED NEWS
Dear Customers & Friends, We sincerely invite you to visit CPHI Shanghai 2025, which will be held at the Shanghai New International Expo Center from June 24th to 26st, 2025. The exhibition is expected to reach a scale of over 230,000 square meters, about 100,000 professional visitors from domestic and abroad, and more than 3,500 participating companies. Company Name: Jinan Enlighten Biotechnology Co., Ltd. Exhibition date: June 24-26 Exhibition address: Shanghai New International Expo Center Our booth: Hall E12 C37 Look forward to meeting you at CPHI Shanghai!
The 22nd CPHI China 2024 was held at the Shanghai New International Expo Center from June 19 to 21, 2024. We had a booth at Hall W7 A55, and our teams from R&D, production, and sales departments participated in this exhibition.
Exhibition Name: CPHI Shanghai 2024 Exhibition date: June 19-21 Exhibition address: Shanghai New International Expo Center Our booth: Hall W7 A55 Look forward to meeting you at CPHI Shanghai!
In order to enhance communication among colleagues and create a passionate, responsible and happy working atmosphere, Jinan Enlighten Biotech organized a team building activity on May 30, 2024 (Thursday) at the Century Park in the southern mountainous area of Jinan.
On April 3, 2024, Mr.Wei, Chairman of Jinan Enlighten Biotech, Mr. Ding, General Manager, and a delegation of six people went to Shanghe to inspect the Health and Pharmaceutical Industry Valley project, laying out the development plan for Wutong group in the next ten years.
Feb 29th to Mar 2nd, Jinan Enlighten Biotech attended Asia Pharma Expo 2024 at Dhaka, which is the largest pharmaceutical machinery and technology exhibition in Bangladesh. The exhibited products included pharmaceutical industry machinery and equipment, APIs, raw materials, pharmaceutical intermediates, excipents and other packaging products. This Expo is an important pharmaceutical information exchange platform in Bangladesh and surrounding regions, attracting suppliers and buyers from all over the world.